Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Article in English | LILACS-Express | LILACS | ID: biblio-1421831

ABSTRACT

The emergence and development of resin-based materials, such as resin composites and adhesive systems, have shifted the restorative treatment of anterior teeth with caries lesions and/or fractures. Thus, based on the disadvantages of indirect restorations, direct esthetic restorations are restorative options even for anterior teeth with exten sive loss of hard tissues. This study aimed to describe and discuss the direct resin composite restoration performed to solve the esthetic and functional impairments of the upper anterior teeth with diastemas. The upper left central incisor received total crown preparation for indirect restoration. Clinical results after 10 years were recorded. Considering the clinical characteris tics of dental restorations, it is possible to conclude that direct resin composite restorations reestablished the esthetic and functional properties satisfactorily, even in a tooth with extensive coronal destruction. The success of the restorative treatm ent was dependent on factors related to the materials´ properties, oral habits of the patient, and mostly the clinical skills of th e dental clinician.


La aparición y el desarrollo de materiales con base de resina, como las resinas compuestas y los sistemas adhesivos, han cambiado el tratamiento restaurador de los dientes anteriores con lesiones de caries y/o fracturas. Por lo tanto, en base a las desventajas de las restauraciones indirectas, las restauraciones estéticas directas son opciones de restauración, incluso para los dientes anteriores con una gran pérdida de tejidos duros. Este estudio tuvo como objetivo describir y discutir la restauración directa con resina compuesta, realizada para solucionar las deficiencias estéticas y funcionales de los dientes anteriores superiores con diastemas. El incisivo central superior izquierdo recibió preparación de corona total para restauración indirecta. Se registraron los resultados clínicos después de 10 años. Considerando las características clínicas de las restauraciones dentales, es posible concluir que las restauraciones directas en resina compuesta restablecieron las propiedades estéticas y funcionales satisfactoriamente, incluso en un diente con destrucción coronal extensa. El éxito del tratamiento restaurador dependió de factores relacionados con las propiedades de los materiales, los hábitos bucales del paciente y, sobre todo, las habilidades clínicas del odontólogo.

2.
Braz. dent. sci ; 25(2): 1-8, 2022. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1369986

ABSTRACT

Objective: To evaluate color and surface gloss stability of bis-acryl resins and resin composites, submitted to artificial staining with cigarette smoke. Material and Methods: Specimens of each material were prepared (n=15). Two resin composites (GrandioSO [RCG], Filtek Supreme [RCZ]) and five bis-acryl resins (Luxatemp Star [BisLUX], Protemp4 [BisPRO], Structor3 [BisSTR], Visalys Temp [BisVIS] and Yprov [BisYPR]) were tested. Initial color was assessed using a spectrophotometer and surface gloss with a glossmeter. Samples were submitted to smoke exposure (10 cigarettes under 8 minutes per cycle). After 3 and 6 cycles, color and gloss were reassessed. Final readings were performed after brush prophylaxis. Data were analyzed using two-way repeated ANOVA and Tukey's test (p<0.05). Results: Differences and interaction of factors (p<0.01) were detected for both color and gloss readings. Resin composites were the least affected by aging, with gloss reduction after prophylaxis. Differences were detected among bis-acryl resins, with better results for BisLUX and BisPRO. BisPRO and BisSTR, showed reduction in gloss after 60 cigarettes, while BisYPR gloss decreased at all evaluated periods. Conclusion: Resin composites are less susceptible to changes after smoke exposure, while bis-acryl resins results are brand-dependent. Prophylaxis negatively influenced the surface gloss of most of the tested materials (AU)


Objetivo: Avaliar a estabilidade de cor e brilho superficial de resinas compostas e bisacrílicas, submetidos ao manchamento artificial por fumaça de cigarro. Material e Métodos: Foram preparados espécimes de cada material (n=15). Duas resinas compostas (GrandioSO [RCG], Filtek Supreme [RCZ]) e cinco resinas bisacrílicas (Luxatemp Star [BisLUX], Protemp4 [BisPRO], Structor3 [BisSTR], Visalys Temp [BisVIS] e Yprov [BisYPR]) foram testados. A cor inicial foi avaliada usando um espectrofotômetro e o brilho de superfície com um medidor de brilho. As amostras foram submetidas à exposição de fumaça de cigarro (10 cigarros com até 8 minutos por ciclo). Após 3 e 6 ciclos, a cor e o brilho foram reavaliados. As leituras finais foram realizadas após a profilaxia escova de robinson. Os dados foram analisados usando de medidas repetidas e teste de Tukey (p<0,05). Resultados: Foram detectadas diferenças e interação de fatores (p<0,01) tanto para leituras de cor quanto para leituras de brilho. As resinas compostas foram as menos afetados pelo envelhecimento, com redução do brilho após a profilaxia. Foram detectadas diferenças entre as resinas bisacrílicas, com melhores resultados para BisLUX e BisPRO. BisPRO e BisSTR, mostraram redução de brilho após 60 cigarros, enquanto que o brilho da BisYPR diminuiu em todos os períodos avaliados. Conclusão: As resinas compostas são as menos suscetíveis a mudanças após a exposição à fumaça, enquanto os resultados das resinas bisacrílicas são dependentes da marca. A profilaxia influenciou negativamente o brilho de superfície da maioria dos materiais testados.(AU)


Subject(s)
Smoke , Color , Composite Resins , Dental Restoration, Temporary
3.
Rev. Odontol. Araçatuba (Impr.) ; 38(3): 9-14, set.-dez. 2017. ilus
Article in Portuguese | LILACS, BBO | ID: biblio-881640

ABSTRACT

Atualmente, o DSD (digital smile design) tem sido utilizado como um recurso de grande destaque para a Odontologia Estética. O uso de um software pode facilitar e implementar através de simulações o tratamento reabilitador estético, fazendo com que haja maior entendimento do paciente sobre o procedimento e seus resultados, bem como evitando equívocos que possam ocorrer durante o tratamento. A técnica consiste em analisar as proporções faciais e dentárias de cada paciente e suas relações com dentes, lábios e gengivas por meio de fotografias digitais e vídeos. Com isso, são realizados desenhos seguindo métodos específicos que podem ser apresentados de maneira simples, compreensível e cativante para o paciente(AU)


Nowadays, the DSD (digital smile design) has been used as a great resource for aesthetic restorative dentistry. Through simulations, the use of a software can facilitate and implement aesthetics rehabilitation treatment, helping the patient to have a better understanding of the procedure and its outcomes, and also avoiding misunderstandings that may occur during the treatment. This technique consists in analyzing facial and dental proportions of each patient and the relations with their teeth, lips and gum through digital photograph and movies. Therefore, designs are made following specific methods that can be presented in a simple way, understandable and engaging for the patient(AU)


Subject(s)
Humans , Female , Adult , Smiling , Dental Restoration, Temporary , Esthetics, Dental , Software Design
4.
Araçatuba; s.n; 2017. 48 p. tab, graf, ilus.
Thesis in Portuguese | LILACS, BBO | ID: biblio-911541

ABSTRACT

Objetivo: Avaliar através de simulação clínica a efetividade da remoção de resíduos fluorescentes do esmalte dental bovino, após remoção de bráquetes ortodônticos, utilizando dispositivos emissores de luz branca e fluorescente. Materiais e Métodos: 180 dentes bovinos anteriores hígidos foram seccionados em discos de esmalte/dentina. A remoção do material resinoso cimentante foi realizada por três operadores. Os dentes foram divididos em quatro grupos de estudo. Os fatores em estudo foram: a fonte de iluminação empregada durante a remoção dos materiais resinosos cimentantes de bráquetes ortodônticos em 4 níveis (n = 45): Convencional (C), LED branco (W), LED fluorescente (F) e fotopolimerizador com filtro fluorescente (FL). Foram consideradas como variáveis de resposta: o tempo para remoção dos resíduos das amostras; a área de remanescente resinoso fluorescente superficial e a mensuração da altura de material adesivo fluorescente remanescente (PICO) e a profundada de esmalte desgastado (VALE). Na comparação entre as técnicas empregou-se o teste Kruskal-Wallis seguido do pós-teste Mann-Whitney U (P≤0,05). Resultados: As Técnicas F e FL apresentaram-se, estatisticamente, semelhantes e as menores medianas de tempo consumido para a remoção do resíduo resinoso. As técnicas C e W apresentaram estatisticamente, a presença de maiores e semelhantes medianas de áreas fluorescentes remanescentes e de PICO (altura do remanescente), com relação as técnicas F e FL; enquanto que as técnicas FL e F postaram, estatisticamente, uma maior mediana de VALE que a técnica C. Conclusões: A associação de emissor de luz fluorescente com um material resinoso fluorescente, colaborou significativamente e de forma eficaz, na redução do tempo consumido para remoção e evidenciação dos resíduos resinosos cimentantes fluorescentes, possibilitando uma remoção efetiva, após a remoção dos bráquetes ortodônticos(AU)


Objective: Evaluate, through clinical simulation, the effectiveness on the removal of fluorescent resin residues from bovine dental enamel after brackets debonding using white and fluorescent light emitting devices. Materials and Methods: 180 healthy anterior bovine teeth were sectioned on enamel / dentin disks. The removal of the resinous material was performed by three operators. The teeth were divided into four groups. The factors studied were: the light source used to remove orthodontic resin residue in 4 levels (n = 45): Conventional (C), white LED (W), fluorescent LED (F) and photocuring unit with Fluorescent filter (FL). Response variables were: the time spent to remove the sample residues; The surface area of the fluorescent remaining resin and the depth measurement of the remaining fluorescent adhesive thickness (PEAK) and the enamel thickness removed (VALLEY). In the comparison between the techniques, the Kruskal-Wallis test was used, followed by the Mann-Whitney U post-test (P≤0.05). Results: In terms of time, the groups F and FL were similar to each other and statistically different for groups C and W. The techniques C and W presented statistically, the presence of larger and similar medians of remaining fluorescent areas, in relation to the F and FL techniques. The techniques C and W presented, statistically, a larger and similar median of peaks than the F and FL techniques. The FL technique statistically demonstrated a higher median of valleys than the C technique. The W, F and FL techniques were statistically similar to each other, as were C and W techniques. Conclusions: Fluorescent light with a fluorescent resinous material, significantly and effectively collaborated in the reduction of the time consumed for evidencing and removal of fluorescent resin residues, allowing an efficient removal after removal of orthodontic brackets(AU)


Subject(s)
Dental Debonding , Dental Enamel , Orthodontic Brackets , Fluorescence
5.
Londrina; s.n; 2013. 54 p. ilus, tab.
Thesis in Portuguese | LILACS, BBO | ID: lil-706470

ABSTRACT

Foi analisado por espectro de Ressonância Paramagnética Eletrônica (RPE), a concentração de radicais livres (RL) formados quando da cimentação de pino de fibra de vidro (PFV), com cimento resinoso dual (CRD), bem como a influência da forma anatômica do PFV (cônico ou cilíndrico). A primeira etapa foi composta de 3 grupos, de acordo com o método de cimentação do PFV numa matriz de silicone: G1- CRD fotopolimerizado por 40 segundos, com aparelho fotopolimerizador de diodo emissor de luz (LED), com potência de 1.500mW/cm2, encostado à superfície externa do pino; G2- CRD não recebeu ativação física; G3- tratamento semelhante ao G1, mas com bloqueio da interface pino/silicone. Na segunda etapa, os PFV foram seccionados de forma a obter dois pinos: PFVCl, cilíndrico e PFVCn cônico, de 9,5mm de comprimento cada, cimentadas semelhantemente ao G1. A concentração de radicais livres foi avaliada em: T0-10 minutos após espatulação do cimento e T1-24 horas após, em secções obtidas em diferentes profundidades do PFV. A análise do espectro das ressonâncias indicou que G1 e G3, apresentaram maior CRL. A translucidez do pino não influenciou na concentração de RL em profundidades acima de 12mm. Os pinos cilíndricos apresentaram maior concentração de RL. A concentração de radicais livres é influenciada pelo método de polimerização, bem como pela forma anatômica do PFV; a capacidade de condução da luz pelo PFV não interfere no grau de conversão do CRD nas regiões de maior profundidade.


The free radical concentration (FR) formed during GFP cementation, using dual cure resin cement (DCRC), as well as the influence of the anatomical shape of the GFP (conical or cylindrical), were analyzed by Electron Paramagnetic Resonance (EPR) spectrum. The first stage consisted of 3 groups, according to the GFP cementation method in a silicone matrix: G1- DCRC light cured for 40 seconds, with light emitting diode (LED), with intensity of 1.500mW/cm2 , leaning against the outer surface of the post; G2 - DCRC without light activation; G3- treatment similar to G1, but blocking the post/matrix interface. In the second stage, GFP were sectioned to obtain two sections: PFVCl, cylindrical and PFVCn, conical, 9,5mm in length each, cemented similarly to G1. The FRC was evaluated in: T0-10 minutes after cement's spatulation e T1-24 hours after, in sections obtained from different GFP depths. The resonance spectrum analysis indicated that G1 and G3 had a greater FR concentration. Post translucency did not influenced the FRC at depths greater than 12mm. Cylindrical posts presented greater FRC. The FR concentration is influenced by the polymerization method, as well as the GFP anatomical shape; GFP capacity to conduct light does not interferes in the degree of conversion on DCRC in regions of greater depth.


Subject(s)
Dental Cements , Dental Materials , Dental Pins , Electron Spin Resonance Spectroscopy , Free Radicals , Polymerization , Post and Core Technique
SELECTION OF CITATIONS
SEARCH DETAIL